Waterproof Ultrasonic Module JSN-SR04T (Integrated Distance Measuring Transducer Sensor)
Diymore ultrasonic module for arduino, waterproof built-in distance measuring module
Product Description
SPECIFICATION:
- Electrical parameters: JSN-SR04T
- Operating voltage: DC 3 ~5.5V
- Quiescent current: < 8mA
- Acoustic emission frequency: 40khz
- Farthest range: 600cm
- Recent range: 20cm
- Distance measurement accuracy: ± 1cm
- Resolution: 1mm
- Measuring angle: 75 degrees
- Input trigger signal: TTL pulse above 10uS
- Serial send command: 0X55
- Output echo signal: Output pulse width level signal, or TTL
- 3-5.5V (power positive)
- Trig (RX) RX
- Echo (output) TX
- GND (power supply negative
- Product Size: L42 * W29 * H12 mm
- Working temperature: -20 ℃ – +70 ℃
- Product color: PCB board is blue
Product Features
- 1.Small size, easy to use
- 2. low power consumption
- 3. High accuracy
- 4, detection of blind spots, farther away
- 5, the output method of diversification, pulse width output, serial output
Note:
- This module should not be charged connection, to live connection, then let the module first GND connected, otherwise it will affect the normal work of the module.
- Ranging, the measured object area of not less than 0.5 square meters and the plane as required to smooth, otherwise affect the measurement results.
The default working mode is Mode 1:
- Mode 1: R27 = open that is not welding. The pattern is described below
- Basic working principle:
- Using IO port TRIG trigger range, to a minimum of 10us high letter.
- Module automatically send 8 40khz square wave, automatically detect whether the signal back;
- There is a signal to return, through the IO port ECHO output a high level, the high level of continuous time is the ultrasound
- From the time of launch to return. Test distance = (high time * sound velocity (340M / s)) / 2;
- When the module is triggered, if no echo is received (the reason is more than the measured range or the probe is not positive On the measured object),
- ECHO port will automatically become low after 60MS, marking the end of the measurement, regardless Power or not.
- LED indicator, LED non-power indicator, it will receive the trigger signal after the module, this When the module is in working condition.
- Only need to provide a pulse above 10uS trigger signal, the module will be issued within 8 40kHz cycle levels and detect echo. The echo signal is output once an echo signal is detected. Reverberations
- The pulse width of the pulse is proportional to the measured distance. Thereby by transmitting a signal to the received echo signal time interval
- Can calculate the distance. Formula: uS / 58 = cm or uS / 148 = inches; or: distance = high time *Sound speed (340M / S) / 2;
- The recommended measurement period is 60ms or more to prevent the impact of the transmitted signal on the echo signal.
Mode 2: R27 = 47K is the welding 47K resistance. The pattern is described below:
- Serial output format for the TTL level, that: 100MS module for the cycle of automatic transmission
- The value of the distance, in mm. Serial baud rate: 9600, n, 8,1.
- Module power recognition, directly into the work mode, the module to conduct a distance every 100ms range,
- And outputs one frame from the pin TX with four 8-bit data. The frame format is: 0XFF + H_DATA + L_DATA + SUM
- 1.0XFF: for a frame to start the data, used to judge;
- 2.H_DATA: the upper 8 bits of the distance data;
- 3.L_DATA: the lower 8 bits of the distance data;
- 4.SUM: data and, for the effect of its 0XFF + H_DATA + L_DATA = SUM (only low 8)
- Note: H_DATA and L_DATA synthesize 16-bit data, that is, the distance in millimeters.
- Description: The module outputs the nearest distance value in the dead zone. If the module does not measure data or is out of range Measured output 0.
- LED indicator, LED non-power indicator, the module connected to work after the light, then the module is in Working state.
Mode 3: R27 = 120K is the welding 120K resistance. In the serial port mode :
- Module power recognition, the module into the standby state, the serial output format for the TTL level, the serial port baud rate:
- 9600, n, 8, 1. When the RX port receives the 0X55 instruction, the module starts a ranging and outputs from the pin TXOut of a frame with 4 8-bit data.
- The frame format is: 0XFF + H_DATA + L_DATA + SUM
- 1.0XFF: for a frame to start the data, used to judge;
- 2.H_DATA: the upper 8 bits of the distance data;
- 3.L_DATA: the lower 8 bits of the distance data;
- 4.SUM: data and, for the effect of its 0XFF + H_DATA + L_DATA = SUM (only low 8)
- Note: H_DATA and L_DATA synthesize 16-bit data, that is, the distance in millimeters
- Description: The module outputs the nearest distance value in the dead zone. If the module does not measure data or is out of range Measured output 0.
- LED indicator, LED non-power indicator, it will receive the 0X55 trigger signal in the module, this When the module is in working condition.